| Availability: | |
|---|---|
| Quantity: | |
IMAX4060
EMAX
An AC Resistive RL Load Bank is a professional load testing solution designed to simulate real electrical loads by combining resistive and inductive elements.
It is widely used for generator testing, UPS commissioning, power system maintenance, and other critical applications where accurate load simulation is required.
WorldRST AC Resistive RL Load Banks are engineered to deliver stable, precise, and safe load testing, helping engineers verify system performance, reliability, and compliance with international standards.
An AC Resistive RL Load Bank applies a controlled resistive (R) and inductive (L) load to electrical power sources, closely replicating real-world operating conditions.
Compared with pure resistive load banks, RL load banks provide more realistic testing results, especially for generators and power systems that operate with inductive loads in actual environments.
Key benefits include:
Accurate simulation of real operating loads
Reliable testing of generators, UPS systems, and power supplies
Improved system stability and performance validation
Precise Load Control
Step-by-step load adjustment ensures accurate testing under different operating conditions.
Wide Power Range
Available in multiple power ratings to meet small-scale and large-capacity testing requirements.
Robust Safety Protection
Integrated over-temperature, overload, short-circuit, and emergency shutdown protection.
Efficient Cooling System
Optimized airflow design ensures stable operation during continuous or high-load testing.
Durable Industrial Design
Built with high-quality components for long service life in demanding environments.
WorldRST AC Resistive RL Load Banks are widely used in:
Generator Load Testing & Commissioning
UPS System Testing and Maintenance
Data Centers & Critical Power Facilities
Power Plants and Substations
Industrial Electrical System Commissioning
These applications help ensure equipment reliability before operation or after maintenance.
Specifications may vary depending on project requirements.
Load Type: AC Resistive + Inductive (RL)
Power Range: Customizable (e.g. 20kW – 1000kW or higher)
Voltage: According to application requirements
Frequency: 50Hz / 60Hz
Cooling Method: Forced air cooling
Control Mode: Manual / Remote / Intelligent control (optional)
Protection: Over-temperature, overload, short-circuit, emergency stop
Custom specifications are available upon request.
Name | Single phase resistive load -RL | ||
Model | IMAX3210-25k | IMAX3210-50k | IMAX3210-100k |
Rated Voltage | 1P2W,AC230V/220V/110V | ||
Resistive Power | 20kW | 40kW | 80kW |
Inductive power | 15kVar | 30kVar | 75kVar |
Rated Frequency | 50/60Hz | 50/60Hz | 50/60Hz |
Loading Mode | Step and shift loading | ||
Load Characteristic | Integrated resistance | ||
Load Stepping | The minimum resistance step size is 0.1kW/0.1kVar | ||
Main test items | Power supply detection long - term load, switching device life test | ||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | ||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | ||
Noise | ≤70dB | ≤73dB | ≤75dB |
Air Outlet Mode | Side wind in, side wind out
| Wind in from the side down and out from the top
| |
Display Accuracy | 0.1V,0.1A | ||
Control Mode | Local manual control: Local button/air switch/touch screen control | ||
Remote intelligent control: RS485/CAN/ Ethernet | |||
Place of Use | Indoor | ||
Weight | 120kg | 220kg | 350kg |
Size | W600mm×D800mm×H800mm | W800mm×D800mm×H1400mm | W800mm×D800mm×H1600mm |
Name | Three-phase resistive load -RL | |||||
Model | IMAX3230-125k | IMAX3230-250k | IMAX3230-500k | IMAX3230-625k | IMAX3230-750k | IMAX3230-1000k |
Rated Voltage | 3P4W,AC220V/380V/400V/415V/440V | |||||
Resistive Power | 100kW | 200kW | 400kW | 500kW | 600kW | 800kW |
Inductive power | 75kVar | 150kVar | 300kVar | 375kVar | 450kVar | 600kVar |
Rated Frequency | 50/60Hz | |||||
Loading Mode | Step loading | |||||
Load Characteristic | Integrated resistance | |||||
Load Stepping | The minimum resistance step length is 1kW/1kVar | |||||
Main test items | Power supply detection long - term load, switching device life test | |||||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | |||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | |||||
Noise | ≤75dB | ≤80dB | ≤85dB | |||
Air Outlet Mode | Wind in from the side down and out from the top. | Side down ejection/side in side out | Wind in from the side down and out from the top. | |||
Display Accuracy | 0.1V,0.1A | |||||
Control Mode | Local manual control: Local button/air switch | Local manual control: through the load box 7 inch LCD touch screen. | ||||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | |||||
Place of Use | Indoor | Indoor/Outdoor | ||||
Weight | 350kg | 650kg | 1100kg | 1350kg | 1650kg | 2300kg |
Size | W800mm×D800mm×H1600mm | W1000mm×D1200mm×H1600mm | W1200mm*D1400mm*1800mm |
| W1800mm×D1600mm×H2000mm | W2000mm×D1800mm×H2000mm |
Professional Engineering Experience
Designed by experienced engineers with deep knowledge of power testing systems.
Customized Solutions
Load banks tailored to voltage, capacity, control, and application needs.
Strict Quality Control
Manufactured under strict quality standards to ensure safety and performance.
Reliable Technical Support
Pre-sales consultation and after-sales technical assistance available.
A resistive load bank only simulates resistive loads, while an RL load bank combines resistive and inductive loads, providing more realistic testing conditions for generators and power systems.
Yes. AC Resistive RL Load Banks are widely used for generator load testing, commissioning, and routine maintenance.
Absolutely. Power capacity, voltage level, control mode, enclosure type, and other parameters can be customized.
Standard safety protections include over-temperature protection, overload protection, short-circuit protection, and emergency stop.
An AC Resistive RL Load Bank is a professional load testing solution designed to simulate real electrical loads by combining resistive and inductive elements.
It is widely used for generator testing, UPS commissioning, power system maintenance, and other critical applications where accurate load simulation is required.
WorldRST AC Resistive RL Load Banks are engineered to deliver stable, precise, and safe load testing, helping engineers verify system performance, reliability, and compliance with international standards.
An AC Resistive RL Load Bank applies a controlled resistive (R) and inductive (L) load to electrical power sources, closely replicating real-world operating conditions.
Compared with pure resistive load banks, RL load banks provide more realistic testing results, especially for generators and power systems that operate with inductive loads in actual environments.
Key benefits include:
Accurate simulation of real operating loads
Reliable testing of generators, UPS systems, and power supplies
Improved system stability and performance validation
Precise Load Control
Step-by-step load adjustment ensures accurate testing under different operating conditions.
Wide Power Range
Available in multiple power ratings to meet small-scale and large-capacity testing requirements.
Robust Safety Protection
Integrated over-temperature, overload, short-circuit, and emergency shutdown protection.
Efficient Cooling System
Optimized airflow design ensures stable operation during continuous or high-load testing.
Durable Industrial Design
Built with high-quality components for long service life in demanding environments.
WorldRST AC Resistive RL Load Banks are widely used in:
Generator Load Testing & Commissioning
UPS System Testing and Maintenance
Data Centers & Critical Power Facilities
Power Plants and Substations
Industrial Electrical System Commissioning
These applications help ensure equipment reliability before operation or after maintenance.
Specifications may vary depending on project requirements.
Load Type: AC Resistive + Inductive (RL)
Power Range: Customizable (e.g. 20kW – 1000kW or higher)
Voltage: According to application requirements
Frequency: 50Hz / 60Hz
Cooling Method: Forced air cooling
Control Mode: Manual / Remote / Intelligent control (optional)
Protection: Over-temperature, overload, short-circuit, emergency stop
Custom specifications are available upon request.
Name | Single phase resistive load -RL | ||
Model | IMAX3210-25k | IMAX3210-50k | IMAX3210-100k |
Rated Voltage | 1P2W,AC230V/220V/110V | ||
Resistive Power | 20kW | 40kW | 80kW |
Inductive power | 15kVar | 30kVar | 75kVar |
Rated Frequency | 50/60Hz | 50/60Hz | 50/60Hz |
Loading Mode | Step and shift loading | ||
Load Characteristic | Integrated resistance | ||
Load Stepping | The minimum resistance step size is 0.1kW/0.1kVar | ||
Main test items | Power supply detection long - term load, switching device life test | ||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | ||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | ||
Noise | ≤70dB | ≤73dB | ≤75dB |
Air Outlet Mode | Side wind in, side wind out
| Wind in from the side down and out from the top
| |
Display Accuracy | 0.1V,0.1A | ||
Control Mode | Local manual control: Local button/air switch/touch screen control | ||
Remote intelligent control: RS485/CAN/ Ethernet | |||
Place of Use | Indoor | ||
Weight | 120kg | 220kg | 350kg |
Size | W600mm×D800mm×H800mm | W800mm×D800mm×H1400mm | W800mm×D800mm×H1600mm |
Name | Three-phase resistive load -RL | |||||
Model | IMAX3230-125k | IMAX3230-250k | IMAX3230-500k | IMAX3230-625k | IMAX3230-750k | IMAX3230-1000k |
Rated Voltage | 3P4W,AC220V/380V/400V/415V/440V | |||||
Resistive Power | 100kW | 200kW | 400kW | 500kW | 600kW | 800kW |
Inductive power | 75kVar | 150kVar | 300kVar | 375kVar | 450kVar | 600kVar |
Rated Frequency | 50/60Hz | |||||
Loading Mode | Step loading | |||||
Load Characteristic | Integrated resistance | |||||
Load Stepping | The minimum resistance step length is 1kW/1kVar | |||||
Main test items | Power supply detection long - term load, switching device life test | |||||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | |||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | |||||
Noise | ≤75dB | ≤80dB | ≤85dB | |||
Air Outlet Mode | Wind in from the side down and out from the top. | Side down ejection/side in side out | Wind in from the side down and out from the top. | |||
Display Accuracy | 0.1V,0.1A | |||||
Control Mode | Local manual control: Local button/air switch | Local manual control: through the load box 7 inch LCD touch screen. | ||||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | |||||
Place of Use | Indoor | Indoor/Outdoor | ||||
Weight | 350kg | 650kg | 1100kg | 1350kg | 1650kg | 2300kg |
Size | W800mm×D800mm×H1600mm | W1000mm×D1200mm×H1600mm | W1200mm*D1400mm*1800mm |
| W1800mm×D1600mm×H2000mm | W2000mm×D1800mm×H2000mm |
Professional Engineering Experience
Designed by experienced engineers with deep knowledge of power testing systems.
Customized Solutions
Load banks tailored to voltage, capacity, control, and application needs.
Strict Quality Control
Manufactured under strict quality standards to ensure safety and performance.
Reliable Technical Support
Pre-sales consultation and after-sales technical assistance available.
A resistive load bank only simulates resistive loads, while an RL load bank combines resistive and inductive loads, providing more realistic testing conditions for generators and power systems.
Yes. AC Resistive RL Load Banks are widely used for generator load testing, commissioning, and routine maintenance.
Absolutely. Power capacity, voltage level, control mode, enclosure type, and other parameters can be customized.
Standard safety protections include over-temperature protection, overload protection, short-circuit protection, and emergency stop.